Three phase hybrid Inverter (HV) 50kW
Login to view price
- 10-year warranty. Replace new machines instead of repairing.
- No need to worry about after-sales between inverters and batteries of different brands.
- Integrated humanized design, removed redundant cables.
- Adds points to beauty and attractiveness.
- Stack installation with Plug & Play connection.
- Makes the installation process time-saving, cost-effective and worry-free.
- Charging electric vehicles with clean energy, effectively save charging costs.
Description
PV (Input)
| Specification |
Value |
| Max. recommended PV array power [Wp] |
60000 |
| Max. PV input voltage [V] |
1000 |
| Rated PV input voltage [V] |
650 |
| Start-up input voltage [V] |
150 |
| MPPT voltage range [V] |
150-950 |
| No. of MPPT / Strings per MPPT |
3 (2/2/2) |
| Max. PV input current [A] |
96 (32/32/32) |
| Max. DC short-circuit current [A] |
120 (40/40/40) |
Battery (Input/Output)
| Specification |
Value |
| Battery type |
Li-ion battery |
| Battery voltage range [V] |
100-800 |
| Max. charge/discharge current [A] |
65/65 |
| Max. charge/discharge power [W] |
50000/50000 |
Grid (Input/Output)
| Specification |
Value |
| Max. AC power from grid |
55000 W / 55000 VA |
| Rated AC output power [VA] |
50000 |
| Max. AC output power [VA] |
50000 |
| Max. AC output current [A] |
75.8 |
| Rated voltage [V] |
3 / N / PE, 220/380; 230/400; 240/415 |
| AC voltage range [V] |
270-480 |
| Rated grid frequency [Hz] |
50 / 60 |
| Grid frequency range [Hz] |
45–55 / 55–65 |
| Total harmonic distortion (THDi) [%] |
< 3 |
| Power factor / Adjustable power factor |
> 0.99 / 0.8 leading to 0.8 lagging |
Backup Output
| Specification |
Value |
| Rated voltage [V] |
3 / N / PE, 220; 230; 240 |
| Frequency range [Hz] |
50 / 60 |
| THDv (rated power, linear load) [%] |
≤2 |
| Backup switching time [ms] |
< 10 |
| Rated output power (off-grid mode) [VA] |
50000 |
| Peak output power (off-grid mode) |
70000 W / 70000 VA, 10s |
| Max. output power (on-grid mode) |
55000 W / 55000 VA |
| Max. output current (on-grid mode) [A] |
3*80 |
Efficiency
| Specification |
Value |
| Max. efficiency / European efficiency [%] |
98.20 / 97.90 |
Protection & Functions
| Feature |
Available |
| Parallel |
Master-slave mode |
| Surge protection |
Type II, DC and AC |
| Overvoltage category |
II DC and III AC |
| Protective class |
Class I |
| Grid monitoring |
Yes |
| DC reverse polarity protection |
Yes |
| Battery input reverse polarity protection |
Yes |
| Insulation monitoring |
Yes |
| AC short-circuit protection |
Yes |
| Residual current protection |
Yes |
| DC switch (PV) |
Yes |
| Over-heat protection |
Yes |
| AFCI |
OPT |
General Data
| Specification |
Value |
| Topology (PV/Battery) |
Transformerless |
| Degree of protection |
IP66 |
| Dimensions (W×H×D) [mm] |
615 × 465 × 255 |
| Weight [kg] |
39.5 |
| Mounting method |
Wall-mounting bracket |
| Operating ambient temperature [°C] |
-25 to 60 (Derating above 45°C) |
| Allowable humidity [%] (non-condensing) |
0–100 |
| Cooling method |
Fan cooling |
| Noise (Typical) |
55 dB (A) |
| Max. operating altitude [m] |
2000 |
| Display |
LED |
| Communication |
2×RS485 / 2×CAN / WLAN |
| DI/DO |
4×DI / 2×DO / DRM0 |
| DC connection type |
MC4 (Max. 6 mm²) |
| Battery connection type |
Plug & play connector (Max.10 mm²) |
| AC connection type |
OT Terminals (Max. 26 mm²) |