Three phase hybrid Inverter (HV) 30kW

Login to view price

  • 10-year warranty. Replace new machines instead of repairing.
  • No need to worry about after-sales between inverters and batteries of different brands.
  • Integrated humanized design, removed redundant cables.
  • Adds points to beauty and attractiveness.
  • Stack installation with Plug & Play connection.
  • Makes the installation process time-saving, cost-effective and worry-free.
  • Charging electric vehicles with clean energy, effectively save charging costs.

Description

PV (Input)

Specification Value
Max. recommended PV array power [Wp] 60000
Max. PV input voltage [V] 1000
Rated PV input voltage [V] 650
Start-up input voltage [V] 150
MPPT voltage range [V] 150-950
No. of MPPT / Strings per MPPT 3 (2/2/2)
Max. PV input current [A] 96 (32/32/32)
Max. DC short-circuit current [A] 120 (40/40/40)

Battery (Input/Output)

Specification Value
Battery type Li-ion battery
Battery voltage range [V] 100-800
Max. charge/discharge current [A] 60/60
Max. charge/discharge power [W] 30000/30000

Grid (Input/Output)

Specification Value
Max. AC power from grid 55000 W / 55000 VA
Rated AC output power [VA] 30000
Max. AC output power [VA] 30000
Max. AC output current [A] 45.5
Rated voltage [V] 3 / N / PE, 220/380; 230/400; 240/415
AC voltage range [V] 270-480
Rated grid frequency [Hz] 50 / 60
Grid frequency range [Hz] 45–55 / 55–65
Total harmonic distortion (THDi) [%] < 3
Power factor / Adjustable power factor > 0.99 / 0.8 leading to 0.8 lagging

Backup Output

Specification Value
Rated voltage [V] 3 / N / PE, 220; 230; 240
Frequency range [Hz] 50 / 60
THDv (rated power, linear load) [%] ≤2
Backup switching time [ms] < 10
Rated output power (off-grid mode) [VA] 30000
Peak output power (off-grid mode) 45000 W / 45000 VA, 10s
Max. output power (on-grid mode) 55000 W / 55000 VA
Max. output current (on-grid mode) [A] 3*80

Efficiency

Specification Value
Max. efficiency / European efficiency [%] 98.20 / 97.80

Protection & Functions

Feature Available
Parallel Master-slave mode
Surge protection Type II, DC and AC
Overvoltage category II DC and III AC
Protective class Class I
Grid monitoring Yes
DC reverse polarity protection Yes
Battery input reverse polarity protection Yes
Insulation monitoring Yes
AC short-circuit protection Yes
Residual current protection Yes
DC switch (PV) Yes
Over-heat protection Yes
AFCI OPT

General Data

Specification Value
Topology (PV/Battery) Transformerless
Degree of protection IP66
Dimensions (W×H×D) [mm] 615 × 465 × 255
Weight [kg] 38
Mounting method Wall-mounting bracket
Operating ambient temperature [°C] -25 to 60 (Derating above 45°C)
Allowable humidity [%] (non-condensing) 0–100
Cooling method Fan cooling
Noise (Typical) 55 dB (A)
Max. operating altitude [m] 2000
Display LED
Communication 2×RS485 / 2×CAN / WLAN
DI/DO 4×DI / 2×DO / DRM0
DC connection type MC4 (Max. 6 mm²)
Battery connection type Plug & play connector (Max.10 mm²)